ref | material | size | size err | size unit | size type | size comment | BET | b nanozyme | b 10n | b unit | specific act | sa 10n | sa unit | comment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
469 | V2O5 nanobelts | 300 | nm | TEM | As shown in Figure 1A,B, the high-magnification SEM image confirmed the fabrication of smooth and straight nanobelts with widths of 200–400 nm. The TEM image in Figure 1C image shows nanobelts with a mean size of ca. 300 nm in width. |
ref | material | enzyme type | substrate | pH | T | km | km err | km 10n | km unit | vmax | vmax err | vmax 10n | vmax unit | kcat | kcat err | kcat 10n | kcat unit | kcat/km | kcat/km
10n | kcat/km unit | comment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
469 | V2O5 nanobelts | OXD | glucose | 7.0 | 37 | 3.02 | mM | 18.114 | -8 | M/s | 469 | 469 | |||||||||
469 | V2O5 nanobelts | POD | TMB | 7.0 | 0.69 | mM | 27.15 | -8 | M/s | 469 | |||||||||||
469 | V2O5 nanobelts | POD | H2O2 | 7.0 | 0.29 | mM | 20.06 | -8 | M/s | 469 |
ref | material | application | target | method | linear range | linear ran unit | LOD | lod unit | recovery | comment |
---|---|---|---|---|---|---|---|---|---|---|
469 | V2O5 nanobelts | glucose detection | glucose | Color | 1-1000 | μM | 0.33 | μM | ||
469 | V2O5 nanobelts | glucose detection | glucose | Color | 1-1000 | μM | 0.33 | μM | Online Monitoring of Glucose in Living Rat Brain |
ref | title | DOI | material type | comment |
---|---|---|---|---|
469 | V2O5 Nanobelts Mimick Tandem Enzymes To Achieve Nonenzymatic Online Monitoring of Glucose in Living Rat Brain | https://doi.org/10.1021/acs.analchem.9b05872 | Metal oxide | V2O5 nanobelts |