Advancement of capture immunoassay for real-time monitoring of hepatitis E virus-infected monkey

References

Loading, please wait
ref
title
DOI
material type
comment
383Advancement of capture immunoassay for real-time monitoring of hepatitis E virus-infected monkeyhttps://doi.org/10.1016/j.aca.2020.02.020MetalAuNPs@Ag

Materials

Loading, please wait
ref
material
size
size err
size unit
size type
size comment
BET
b nanozyme
b 10n
b unit
specific act
sa 10n
sa unit
comment
383AuNPs@Ag24.4nmDLSThe hydrodynamic size of AuNPs were found 13.66 ± 3.66 nm with polydispersity index of 0.273 which increased to 24.4 nm after the Ag deposition, measured by DLS

Kinetics

Loading, please wait
ref
material
enzyme type
substrate
pH
T
km
km err
km 10n
km unit
vmax
vmax err
vmax 10n
vmax unit
kcat
kcat err
kcat 10n
kcat unit
kcat/km
kcat/km 10n
kcat/km unit
comment
383AuNPs@AgPOD383

Applications

Loading, please wait
ref
material
application
target
method
linear range
linear ran unit
LOD
lod unit
recovery
comment
383AuNPs@Agdetect the viral HEV containing in fecal samples collected from HEV-infected monkeyHEV-LPsColor8.75 × 10−8– 10−11g mL−14.3 × 10−12g mL−1