Point-of-care assay for drunken driving with Pd@ Pt core-shell nanoparticles-decorated ploy (vinyl alcohol) aerogel assisted by portable pressure meter

References

Loading, please wait
ref
title
DOI
material type
comment
597Point-of-care assay for drunken driving with Pd@ Pt core-shell nanoparticles-decorated ploy (vinyl alcohol) aerogel assisted by portable pressure meterhttps://doi.org/10.7150/thno.42601CompositePd@Pt core-shell nanoparticles (abbreviated to Pd@Pt). the proposed PAA/Pd@Pt composite (denoted as PAAC) can also work as glucose sensor by replacing the AOX to glucose oxidase (GOX)

Materials

Loading, please wait
ref
material
size
size err
size unit
size type
size comment
BET
b nanozyme
b 10n
b unit
specific act
sa 10n
sa unit
comment
597PAACTEMThe free-standing Pd@Pt have average diameter of ~100 nm (Figure 2C). The two regions highlighted in gray indicate the ~20 nm thickness of the Pt shell, almost consistent with Figure 2D.

Kinetics

Loading, please wait
ref
material
enzyme type
substrate
pH
T
km
km err
km 10n
km unit
vmax
vmax err
vmax 10n
vmax unit
kcat
kcat err
kcat 10n
kcat unit
kcat/km
kcat/km 10n
kcat/km unit
comment
5976-PAAC-30CAT597597

Applications

Loading, please wait
ref
material
application
target
method
linear range
linear ran unit
LOD
lod unit
recovery
comment
5976-PAAC-30alcohol and glucose detectionalcoholE-chem0-6mM0.50mM
5976-PAAC-30alcohol and glucose detectionglucoseE-chem0-40mM2.50mM