ref | title | DOI | material type | comment |
---|---|---|---|---|
1323 | Platinum nanozyme-encapsulated poly (amidoamine) dendrimer for voltammetric immunoassay of pro-gastrin-releasing peptide | https://doi.org/10.1016/j.aca.2020.08.026 | Metal | platinum nanoparticles encapsulated inside dendrimers (PtDEN) |
ref | material | enzyme type | substrate | pH | T | km | km err | km 10n | km unit | vmax | vmax err | vmax 10n | vmax unit | kcat | kcat err | kcat 10n | kcat unit | kcat/km | kcat/km
10n | kcat/km unit | comment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No matching records found |
ref | material | application | target | method | linear range | linear ran unit | LOD | lod unit | recovery | comment |
---|---|---|---|---|---|---|---|---|---|---|
1323 | Detection of pro-gastrin-releasing peptide | pro-gastrin-releasing peptide | E-chem | 0.001-10 | ng/mL | 0.86 | ng/mL |