ref | material | size | size err | size unit | size type | size comment | BET | b nanozyme | b 10n | b unit | specific act | sa 10n | sa unit | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7729 | 500 | CNF/FeCDs | 4 | 0.9 | nm | DLS | The corresponding size-distribution analysis (Fig. 1b) unveiled their narrow size distribution in the range of 2–7 nm with a mean diameter of 4.0 ± 0.9 nm, which confirmed that it was a good candidate for doping additive. |
ref | material | enzyme type | substrate | pH | T | km | km err | km 10n | km unit | vmax | vmax err | vmax 10n | vmax unit | kcat | kcat err | kcat 10n | kcat unit | kcat/km | kcat/km 10n | kcat/km unit | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6360 | 500 | CNF/FeCDs | POD | H2O2 | 3.7 | mM | 8.71 | -8 | M/s | 500 | ||||||||||||
6358 | 500 | CNF/FeCDs | POD | TMB | 0.43 | mM | 10 | -8 | M/s | 500 | 500 |
ref | material | application | target | method | linear range | linear ran unit | LOD | lod unit | recovery | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|
5443 | 500 | CNF/FeCDs | Smartphone-based colorimetric detection of hydrogen peroxide and glucose | H2O2 | Color | 6-42 | μM | 0.93 | μM | ||
5444 | 500 | CNF/FeCDs | Smartphone-based colorimetric detection of hydrogen peroxide and glucose | glucose | Color | 10-70 | μM | 1.73 | μM |
ref | title | DOI | material type | comment | |
---|---|---|---|---|---|
3687 | 500 | Cellulose nanofibrils/carbon dots composite nanopapers for the smartphone-based colorimetric detection of hydrogen peroxide and glucose | https://doi.org/10.1016/j.snb.2020.129330 | Composite | Fe-doped carbon dots (FeCDs) immobilized on cellulose nanofibrils (CNF) (CNF/FeCDs) |