ref | material | size | size err | size unit | size type | size comment | BET | b nanozyme | b 10n | b unit | specific act | sa 10n | sa unit | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7513 | 257 | TiO2/C-QDs | 5.23 | 0.3 | nm | TEM | The mean size was 5.23 nm, as calculated from 100 particlesin the TEM image. |
ref | material | enzyme type | substrate | pH | T | km | km err | km 10n | km unit | vmax | vmax err | vmax 10n | vmax unit | kcat | kcat err | kcat 10n | kcat unit | kcat/km | kcat/km 10n | kcat/km unit | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6134 | 257 | TiO2/C-QDs | OXD | TMB | 5 | 25 | 0.158 | mM | 2.5 | -8 | M/s | 6.04 | 1/s | 257 | 257 |
ref | material | application | target | method | linear range | linear ran unit | LOD | lod unit | recovery | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|
5148 | 257 | TiO2/C-QDs | GSH detection | GSH | Color | 0.5-25 | μM | 0.2 | μM | taking human serum as an example, the possibility of applying GSH colorimetry to actual biological samples wasexamined by standard addition methods. | |
5147 | 257 | TiO2/C-QDs | GSH detection | GSH | Color | 0.5-25 | μM | 0.2 | μM |
ref | title | DOI | material type | comment | |
---|---|---|---|---|---|
3467 | 257 | Ti3C2Tx MXene-derived TiO2/C-QDs as oxidase mimics for the efficient diagnosis of glutathione in human serum | https://doi.org/10.1039/c9tb02478f | Composite | quantum dots of TiO2 loaded on carbon (TiO2/C-QDs) |