Amperometric Detection of Glucose and H2O2 Using Peroxide Selective Electrode Based on Carboxymethylcellulose/Polypyrrole and Prussian Blue Nanocomposite

References

ref title DOI material type comment
4472 1302 Amperometric Detection of Glucose and H2O2 Using Peroxide Selective Electrode Based on Carboxymethylcellulose/Polypyrrole and Prussian Blue Nanocomposite https://doi.org/10.1016/j.mtcomm.2020.101839 Composite CMC-PPy-PB nanocomposite film

Materials

ref material size size err size unit size type size comment BET b nanozyme b 10n b unit specific act sa 10n sa unit comment

Kinetics

ref material enzyme type substrate pH T km km err km 10n km unit vmax vmax err vmax 10n vmax unit kcat kcat err kcat 10n kcat unit kcat/km kcat/km 10n kcat/km unit comment

Applications

ref material application target method linear range linear ran unit LOD lod unit recovery comment
6155 1302 ITO/CMC-PPy-PB/GOx Amperometric detection of glucose and H2O2 E-chem 0.02-1.1 mM 5.23 μM
6154 1302 ITO/CMC-PPy-PB/GOx Amperometric detection of glucose and H2O2 H2O2 E-chem 5- 470 μM 0.59 μM