ref | title | DOI | material type | comment |
---|---|---|---|---|
1138 | New micro/nanocomposite with peroxidase-like activity in construction of oxidases-based amperometric biosensors for ethanol and glucose analysis | https://doi.org/10.1016/j.aca.2020.11.052 | Composite | carbon microfibers (CF) by hemin (H) and gold (Au) nanoparticles |
ref | material | size | size err | size unit | size type | size comment | BET | b nanozyme | b 10n | b unit | specific act | sa 10n | sa unit | comment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1138 | CF-H-Au | 200 | μm | SEM | The formation of Au on the surface of CF fragments with a size up to 200 μm (obtained by pre-ultrasonic treatment) is much more efficient (light areas) compared to larger CF fragments (dark areas) (see figs2, figs3). |
ref | material | enzyme type | substrate | pH | T | km | km err | km 10n | km unit | vmax | vmax err | vmax 10n | vmax unit | kcat | kcat err | kcat 10n | kcat unit | kcat/km | kcat/km
10n | kcat/km unit | comment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1138 | GOX–CF–H-Au | POD | glucose | 1.47 | 0.28 | mM | 12.6 | 1.5 | μA | 1138 | |||||||||||
1138 | AOX–CF–H-Au | POD | ethanol | 0.14 | 0.01 | mM | 8.16 | 0.16 | μA | 1138 | |||||||||||
1138 | CF-H | POD | H2O2 | 4.7 | mM | 1138 | |||||||||||||||
1138 | CF-H-Au | POD | H2O2 | 2.87 | mM | 1138 |
ref | material | application | target | method | linear range | linear ran unit | LOD | lod unit | recovery | comment |
---|---|---|---|---|---|---|---|---|---|---|
1138 | GOX–CF–H-Au | detection to glucose | glucose | E-chem | 0.1–0.9 | mM | 0.05 | mM | ||
1138 | AOX–CF–H-Au | detection to ethanol | ethanol | E-chem | 0.01–0.15 | mM | 0.005 | mM |