ref | title | DOI | material type | comment |
---|---|---|---|---|
1443 | ATP induced alteration in the peroxidase-like properties of hollow Prussian blue nanocubes: a platform for alkaline phosphatase detection | https://doi.org/10.1039/d0an00405g | Others | f hollow Prussian blue nanocubes (hPBNCs) |
ref | material | application | target | method | linear range | linear ran unit | LOD | lod unit | recovery | comment |
---|---|---|---|---|---|---|---|---|---|---|
1443 | hPBNCs–ATP | detection of alkaline phosphatase | Alkaline phosphatase (ALP) | Color | 2.5-50 | mU/mL | 1.54 | mU/mL | 97.68%- 105.40% | By utilizing the hPBNCs–ATP-based colorimetric assay, the recoveries of ALP in serum samples were in the range of 97.68% to 105.40% with the relative standard deviations (RSD, n = 3) from 2.13% to 3.22% (Table 2). |