Rosette-shaped graphitic carbon nitride acts as a peroxidase mimic in a wide pH range for fluorescence-based determination of glucose with glucose oxidase.

References

ref title DOI material type comment
3436 205 Rosette-shaped graphitic carbon nitride acts as a peroxidase mimic in a wide pH range for fluorescence-based determination of glucose with glucose oxidase. https://doi.org/10.1007/s00604-020-04249-z Carbon Rosette-shaped graphitic carbon nitride (rosette-GCN)

Materials

ref material size size err size unit size type size comment BET b nanozyme b 10n b unit specific act sa 10n sa unit comment
7490 205 rosette-GCN 2.53 0.78 μm SEM The size of rosette-GCN was estimated to be 2.53 ± 0.78 μM through 20 times measurements in its SEM images. 77.800 ± 0.669

Kinetics

ref material enzyme type substrate pH T km km err km 10n km unit vmax vmax err vmax 10n vmax unit kcat kcat err kcat 10n kcat unit kcat/km kcat/km 10n kcat/km unit comment

Applications

ref material application target method linear range linear ran unit LOD lod unit recovery comment
5118 205 Rosette-GCN glucose was reliably determined glucose Color 5.0-275.0 μM 1.2 μM 99.3–104.1%
5117 205 Rosette-GCN glucose was reliably determined glucose Color 5.0-275.0 μM 1.2 μM 99.3–104.1% These results prove that rosette-GCN-based systems may serve as potent analytical platforms for the diagnosis of high glucose levels in clinical settings.