ref | title | DOI | material type | comment | |
---|---|---|---|---|---|
3471 | 261 | Nanozyme chemiluminescence paper test for rapid and sensitive detection of SARS-CoV-2 antigen | https://doi.org/10.1016/j.bios.2020.112817 | Composite | Co–Fe nanoparticles@hemin |
ref | material | size | size err | size unit | size type | size comment | BET | b nanozyme | b 10n | b unit | specific act | sa 10n | sa unit | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7519 | 261 | Co–Fe@hemin | ~80 | nm | the Co–Fe@hemin nanozymes resemble spherical particles, characterized by an average diameter of approx. 80 nm | 70 | 0 | U/mg | |||||||
7518 | 261 | Co–Fe@hemin | ~80 | nm | the Co–Fe@hemin nanozymes resemble spherical particles, characterized by an average diameter of approx. 80 nm | 69.915 | 0 | U/mg |
ref | material | enzyme type | substrate | pH | T | km | km err | km 10n | km unit | vmax | vmax err | vmax 10n | vmax unit | kcat | kcat err | kcat 10n | kcat unit | kcat/km | kcat/km 10n | kcat/km unit | comment |
---|
ref | material | application | target | method | linear range | linear ran unit | LOD | lod unit | recovery | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|
5153 | 261 | Co–Fe@hemin | Nanozyme chemiluminescence paper test for rapid and sensitive detection of SARS-CoV-2 antigen | CL | 0.2-100 | ng/mL | 0.1 | ng/mL |