Carbon quantum dots originated from chicken blood as peroxidase mimics for colorimetric detection of biothiols

References

ref title DOI material type comment
3397 166 Carbon quantum dots originated from chicken blood as peroxidase mimics for colorimetric detection of biothiols https://doi.org/10.1016/j.jphotochem.2020.112529 Carbon Carbon quantum dots (CQDs) from chicken blood

Materials

ref material size size err size unit size type size comment BET b nanozyme b 10n b unit specific act sa 10n sa unit comment
7458 166 CB-CQDs 1.5-3.6 nm TEM They exhibit a size range of 1.5–3.6 nm with an average diameter of about 2.4 nm, fitting well to the Gaussian function

Kinetics

ref material enzyme type substrate pH T km km err km 10n km unit vmax vmax err vmax 10n vmax unit kcat kcat err kcat 10n kcat unit kcat/km kcat/km 10n kcat/km unit comment
6055 166 CB-CQDs POD TMB 4.5 RT 0.83 mM 5.13 -8 M/s 166 166
6054 166 CB-CQDs POD H2O2 4.5 RT 0.7 mM 4.09 -8 M/s 166

Applications

ref material application target method linear range linear ran unit LOD lod unit recovery comment
5074 166 CB-CQDs The detection of biothiols was performed as follows: in a series of colorimetric tubes, 0.5 mL of TMB (20 mM), 0.5 mL of H2O2 (25 mM), and 0.1 mL of CB-CQDs were fully mixed in 3.8 mL of HAc-NaAc buffer at pH4.5. Then, various concentrations of biothiols standard solution (0.1 mL) were added into the above mixture. After they were well mixed and incubated at 40 °C for 25 min, the absorption spectra were recorded on a Unico 4802 ultraviolet-visible spectrophotometer at room temperature. The calibration curves for biothiols were established according to the decrease of absorbance defined as ΔA=A0﹣A, where A0 and A denote the absorbance at 652 nm without and with analyte, individually. cysteine Color 0.5-20 μM 0.4 μM 95.9±2.7
5073 166 CB-CQDs The detection of biothiols was performed as follows: in a series of colorimetric tubes, 0.5 mL of TMB (20 mM), 0.5 mL of H2O2 (25 mM), and 0.1 mL of CB-CQDs were fully mixed in 3.8 mL of HAc-NaAc buffer at pH4.5. Then, various concentrations of biothiols standard solution (0.1 mL) were added into the above mixture. After they were well mixed and incubated at 40 °C for 25 min, the absorption spectra were recorded on a Unico 4802 ultraviolet-visible spectrophotometer at room temperature. The calibration curves for biothiols were established according to the decrease of absorbance defined as ΔA=A0﹣A, where A0 and A denote the absorbance at 652 nm without and with analyte, individually. cysteine Color 0.5-20 μM 0.4 μM 95.9±2.7 105.7±2.0; 109.3±1.1; 99.7±4.3; 91.5±1.0; 98.2±2.3