Colorimetric glucose sensing with multiple-color changes by using a MnO 2 NSs–TMB nanosystem

References

ref title DOI material type comment
4404 1219 Colorimetric glucose sensing with multiple-color changes by using a MnO 2 NSs–TMB nanosystem https://doi.org/10.1039/D0AY02184A Composite MnO2 NSs–TMB

Materials

ref material size size err size unit size type size comment BET b nanozyme b 10n b unit specific act sa 10n sa unit comment
8245 1219 MnO2 NSs–TMB 50 nm TEM With increasing dosage of BSA from 0.1 mg to 1 mg and the content of MnO2 fixed at 0.02 M, the lateral dimension of MnO2 NSs decreased from above 100 nm (Fig. 2c) to about 50 nm (Fig. 2d).

Kinetics

ref material enzyme type substrate pH T km km err km 10n km unit vmax vmax err vmax 10n vmax unit kcat kcat err kcat 10n kcat unit kcat/km kcat/km 10n kcat/km unit comment
7160 1219 MnO2 NSs–TMB OXD TMB 4.0 37 1219

Applications

ref material application target method linear range linear ran unit LOD lod unit recovery comment
6098 1219 MnO2 NSs–TMB glucose colorimetric detection system glucose Color 0-4000 μM 5.0 μM