ref | title | DOI | material type | comment | |
---|---|---|---|---|---|
3639 | 451 | Construction of photocathodic bioanalytical platform based on Z-scheme polyimide/CdS composite assisted by dual-catalysis system | https://doi.org/10.1016/j.snb.2020.128079 | Composite | Z-scheme polyimide/CdS composite |
ref | material | size | size err | size unit | size type | size comment | BET | b nanozyme | b 10n | b unit | specific act | sa 10n | sa unit | comment |
---|
ref | material | enzyme type | substrate | pH | T | km | km err | km 10n | km unit | vmax | vmax err | vmax 10n | vmax unit | kcat | kcat err | kcat 10n | kcat unit | kcat/km | kcat/km 10n | kcat/km unit | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6307 | 451 | PI/CdS | POD | TMB | 2.127 | mM | 13.98 | -8 | M/s | 451 | 451 | |||||||||||
6306 | 451 | PI/CdS | POD | H2O2 | 479.1 | mM | 3.25 | -8 | M/s | 451 |
ref | material | application | target | method | linear range | linear ran unit | LOD | lod unit | recovery | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|
5367 | 451 | PI/CdS | detection of hypoxanthine | hypoxanthine | E-chem | 0.010-10.0 | mM | 5.28 | μM | 95.5 %–105.9 % | |
5366 | 451 | PI/CdS | detection of hypoxanthine | hypoxanthine | E-chem | 0.010-10.0 | mM | 5.28 | μM | 95.5 %–105.9 % | Human serum samples were diluted 20-fold with phosphate buffer solution (pH 7.4) in advance. |