ref | title | DOI | material type | comment | |
---|---|---|---|---|---|
3713 | 526 | Platinum (II)-doped graphitic carbon nitride with enhanced peroxidase-like activity for detection of glucose and H2O2 | https://doi.org/10.1016/j.saa.2020.118649 | Composite | A platinum (II)-doped graphitic carbon nitride (Pt2+@g-C3N4) nanozyme |
ref | material | size | size err | size unit | size type | size comment | BET | b nanozyme | b 10n | b unit | specific act | sa 10n | sa unit | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7756 | 526 | Pt2+@g-C3N4 |
ref | material | enzyme type | substrate | pH | T | km | km err | km 10n | km unit | vmax | vmax err | vmax 10n | vmax unit | kcat | kcat err | kcat 10n | kcat unit | kcat/km | kcat/km 10n | kcat/km unit | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6390 | 526 | Pt2+@g-C3N4 | Detection of glucose | H2O2 | 4.0 | RT | 1.25 | mM | 7.22 | -8 | M/s | 526 | 526 | |||||||||
6389 | 526 | Pt2+@g-C3N4 | Detection of glucose | TMB | 4.0 | RT | 0.11 | mM | 5.51 | -8 | M/s | 526 | 526 |
ref | material | application | target | method | linear range | linear ran unit | LOD | lod unit | recovery | comment | |
---|---|---|---|---|---|---|---|---|---|---|---|
5469 | 526 | Pt2+@g-C3N4 | for glucose detection | glucose | Color | 13–2000 | μM | 10 | μM |