‘Artificial peroxidase’nanozyme–enzyme based lactate biosensor

References

ref title DOI material type comment
3328 97 ‘Artificial peroxidase’nanozyme–enzyme based lactate biosensor https://doi.org/10.1016/j.talanta.2019.120393 Other Prussian Blue

Materials

ref material size size err size unit size type size comment BET b nanozyme b 10n b unit specific act sa 10n sa unit comment
7400 97 Prussian Blue 49 nm Others Prussian Blue nanoparticles with Ø =49nm were used

Kinetics

ref material enzyme type substrate pH T km km err km 10n km unit vmax vmax err vmax 10n vmax unit kcat kcat err kcat 10n kcat unit kcat/km kcat/km 10n kcat/km unit comment
5988 97 Prussian Blue POD H2O2 3.8 RT 97 97

Applications

ref material application target method linear range linear ran unit LOD lod unit recovery comment
5005 97 Prussian Blue detection of lactate lactate E-chem