    ref material application target method linear range linear range unit LOD LOD unit recovery comment
    5033 134 CTF-1 determination of rutin in tablets and in Flos Sophorae Immaturus rutin CL 0.03–0.25 μmol·L−1 0.015 μmol·L−1 The CL system gave a linear response to the concentration of rutin in the range of 0.03–0.25 μmol·L−1 with a limit of detection of 0.015 μmol·L−1.
    5034 134 CTF-1 determination of rutin in tablets and in Flos Sophorae Immaturus rutin CL 0.03–0.25 μmol·L−1 0.015 μmol·L−1
    5298 388 COF-300-AR The practical application of COF-300-AR oxidase mimic for colorimetric detection of glutathione (GSH) was examined GSH Color 1~15 μM 1.0 μM
    5568 631 Fe-PorCOF Glucose sensing Glucose 0.01to 10.0 μmol·L-1 5.3 nmol·L-1
    5664 741 Fe-COFs detect H2O2 and degrade RhB H2O2 Color 10-2000 μM 5.6 μM 96.27-100.70%